Back
Where to buy Contact us
PHP-LFBCG5-MSL

NH fuse-links gG 500VAC , double indicator/live gripping-lugs size 000, 00, 0, 1, 2, 3

Approvals & Standards
VDE 0636 Part 201
IEC 60269-1 and -2

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Key features & benefits

  • Dimensions according to DIN 43 620 parts 1 to 4

  • Non-isolated gripping lugs

  • Double indicator

  • 0% cadmium

Applications

  • gG: general purpose cable and line protection

Technical Specifications

Amperage Range 2 ... 800 A
Speed/Characteristic gG
CE Conformity Yes
Reach Compliant Yes

Reference Finder

Item number Ampere rating Fuse size Clearing I2t At Rated Voltage Indication System Product weight
D213995 - NH000GG50V6 See product
6A NH000 - Yes 0.13kg
D219285 - NH1GG50V224 See product
224A NH1 - Yes 0.42kg
D219814 - NH0GG50V100 See product
100A NH0 - Yes 0.27kg
D229612 - NH0GG50V224 See product
224A NH0 - Yes 0.27kg
E201185 - NH000GG50V25 See product
25A NH000 - Yes 0.13kg
E201185C - NH000GG50V25/3 See product
25A NH000 - Yes 0.13kg
E201346 - NH2GG50V315 See product
315A NH2 - Yes 0.64kg
E213996 - NH000GG50V63 See product
63A NH000 - Yes 0.13kg
E213996C - NH000GG50V63/3 See product
63A NH000 - Yes 0.13kg
E219815 - NH1GG50V250 See product
250A NH1 - Yes 0.42kg
Back to top