Back
Where to buy Contact us
PHP-LFBCG5-MSL

NH fuse-links gG 500VAC , double indicator/live gripping-lugs size 000, 00, 0, 1, 2, 3

Approvals & Standards
VDE 0636 Part 201
IEC 60269-1 and -2

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Key features & benefits

  • Dimensions according to DIN 43 620 parts 1 to 4

  • Non-isolated gripping lugs

  • Double indicator

  • 0% cadmium

Applications

  • gG: general purpose cable and line protection

Technical Specifications
Amperage Range 2 ... 800 A
Speed/Characteristic gG
CE Conformity Yes
Reach Compliant Yes

Reference Finder

Item number Ampere rating Fuse size Clearing I2t At Rated Voltage Indication System Product weight
L214669 - NH1GG50V63 See product
63A NH1 - Yes 0.28kg
M200801 - NH1GG50V16 See product
16A NH1 - Yes 0.28kg
M211082 - NH2GG50V40 See product
40A NH2 - Yes 0.42kg
M212462 - NH000GG50V4 See product
4A NH000 - Yes 0.13kg
M214670 - NH2GG50V100 See product
100A NH2 - Yes 0.42kg
M217223 - NH3GG50V500 See product
500A NH3 - Yes 1.05kg
N200802 - NH2GG50V25 See product
25A NH2 - Yes 0.42kg
N201860 - NH1GG50V25 See product
25A NH1 - Yes 0.28kg
N211083 - NH2GG50V400 See product
400A NH2 - Yes 0.64kg
N212463 - NH000GG50V40 See product
40A NH000 - Yes 0.13kg
Back to top