NH fuse-links gG 500VAC , double indicator/live gripping-lugs size 000, 00, 0, 1, 2, 3

Approvals & Standards
VDE 0636 Part 201
IEC 60269-1 and -2

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Key features & benefits

  • Dimensions according to DIN 43 620 parts 1 to 4

  • Non-isolated gripping lugs

  • Double indicator

  • 0% cadmium

Applications

  • gG: general purpose cable and line protection

Technical Specifications
Amperage Range 2 ... 800 A
Speed/Characteristic gG
CE Conformity Yes
Reach Compliant Yes

Reference Finder

Item number Ampere rating Fuse size Clearing I2t At Rated Voltage Indication System Product weight
E229613 - NH0GG50V250 See product
250A NH0 - Yes 0.27kg
F223013 - NH0GG50V160 See product
160A NH0 - Yes 0.27kg
G214159 - NH0GG50V10 See product
10A NH0 - Yes 0.27kg
H213148 - NH0GG50V6 See product
6A NH0 - Yes 0.27kg
J217220 - NH0GG50V35 See product
35A NH0 - Yes 0.27kg
K214162 - NH3GG50V355 See product
355A NH3 - Yes 0.65kg
K222097 - NH000GG50V16 See product
16A NH000 - Yes 0.13kg
K222097C - NH000GG50V16/3 See product
16A NH000 - Yes 0.13kg
L211081 - NH1GG50V32 See product
32A NH1 - Yes 0.28kg
L213151 - NH3GG50V315 See product
315A NH3 - Yes 0.65kg
Back to top