Back
Where to buy Contact us
PHP-LFBCGT-MSL

NH fuse-links gTr 400VAC, middle indicator/isolated gripping-lugs size 2, 3

Approvals & Standards
VDE 0636 Part 201
IEC 60269-1 and -2

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base, (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current, it must be handled by a qualified professional.

NH-fuse links „gTr“ are used for the protection of transformers. The time/current characteristic is especially adapted to that of the protected transformer and implies optimal selectivity to NH-fuse links characteristic gG. The fuses can be loaded with 1,3 times nominal current for up to 10 hours. The fuse link operates at 1,5 times nominal transformer current within 2 hours.

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base, (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current, it must be handled by a qualified professional.

NH-fuse links „gTr“ are used for the protection of transformers. The time/current characteristic is especially adapted to that of the protected transformer and implies optimal selectivity to NH-fuse links characteristic gG. The fuses can be loaded with 1,3 times nominal current for up to 10 hours. The fuse link operates at 1,5 times nominal transformer current within 2 hours.

Key features & benefits

  • Maximum transformer capacity (up to 1,3 x In)

  • Reduction of unnecessary interruption of operation

  • Precise cut off of overload

  • Characteristic adapted to the transformer

  • Resistant to ageing

  • Selectivity to fuse links gG

  • High current limiting

  • High breaking capacity

  • Easy selection between transformer and fuse link

Applications

  • Protection of transformers

Technical Specifications

Amperage Range 72 ... 577 A
Speed/Characteristic gTr
CE Conformity Yes
Reach Compliant Yes

Reference Finder

16 references in this series

Scroll

Item number Ampere rating Fuse size Clearing I2t At Rated Voltage Indication System Product weight
D1030541A - NH32GTR315KVA-1 See product
455A NH3 - Yes 1kg
E1030542A - NH32GTR400KVA-1 See product
577A NH3 - Yes 1kg
M1028686 - NH2GTR50KVA-1 See product
72A NH2 - Yes 0.5kg
N1028687 - NH2GTR75KVA-1 See product
108A NH2 - Yes 0.5kg
P1028688 - NH2GTR100KVA-1 See product
144A NH2 - Yes 0.5kg
Q1028689 - NH2GTR125KVA-1 See product
180A NH2 - Yes 0.5kg
Q1030529 - NH22GTR200KVA-1 See product
289A NH2 - Yes 0.5kg
R1028690 - NH2GTR160KVA-1 See product
231A NH2 - Yes 0.5kg
R1030530 - NH22GTR250KVA-1 See product
361A NH2 - Yes 0.5kg
S1030531A - NH3GTR50KVA-1 See product
72A NH3 - Yes 1kg
Back to top