NH fuse-links gG 400VAC , double indicator/isolated gripping-lugs size 000, 00, 1, 2, 3

Approvals & Standards
VDE 0636 Part 201
IEC 60269-1 and -2

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Rated Power Dissipation values of Mersen NH fuse-links 400VAC are below the maximum values required by standard IEC 60269.

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Rated Power Dissipation values of Mersen NH fuse-links 400VAC are below the maximum values required by standard IEC 60269.

Key features & benefits

  • Dimensions according to DIN 43 620 Parts 1 to 4

  • Isolated metal gripping lugs (SGL)

  • Double indicator

  • Lead free contact blades

  • 0% cadmium

Applications

  • gG: general purpose cable and line protection

Technical Specifications

Amperage Range 2 ... 630 A
Speed/Characteristic gG
CE Conformity Yes
Reach Compliant Yes

Reference Finder

Item number Ampere rating Fuse size Clearing I2t At Rated Voltage Indication System Product weight
T223692 - NH000GG40V16-1 See product
16A NH000 - Yes 0.1225kg
V223693 - NH000GG40V20-1 See product
20A NH000 - Yes 0.1225kg
V223716 - NH1GG40V35-1 See product
35A NH1 - Yes 0.2833kg
W223694 - NH000GG40V25-1 See product
25A NH000 - Yes 0.1225kg
W223717 - NH1GG40V50-1 See product
50A NH1 - Yes 0.2833kg
X223695 - NH000GG40V32-1 See product
32A NH000 - Yes 0.1225kg
X223718 - NH1GG40V63-1 See product
63A NH1 - Yes 0.2833kg
X223741 - NH2GG40V80-1 See product
80A NH2 - Yes 0.4233kg
Y223696 - NH000GG40V35-1 See product
35A NH000 - Yes 0.1225kg
Y223719 - NH1GG40V80-1 See product
80A NH1 - Yes 0.2833kg