Back
Where to buy Contact us
PHP-LFBCG5-MSL

NH fuse-links gG 500VAC , double indicator/live gripping-lugs size 000, 00, 0, 1, 2, 3

Approvals & Standards
VDE 0636 Part 201
IEC 60269-1 and -2

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Key features & benefits

  • Dimensions according to DIN 43 620 parts 1 to 4

  • Non-isolated gripping lugs

  • Double indicator

  • 0% cadmium

Applications

  • gG: general purpose cable and line protection

Technical Specifications

Amperage Range 2 ... 800 A
Speed/Characteristic gG
CE Conformity Yes
Reach Compliant Yes

Reference Finder

Item number Ampere rating Fuse size Clearing I2t At Rated Voltage Indication System Product weight
Q218767 - NH2GG50V224 See product
224A NH2 - Yes 0.42kg
Q228519 - NH1GG50V315 See product
315A NH1 - Yes 0.42kg
R1069078 - NH3GG50V63 See product
63A NH3 - Yes 0.65kg
R201863 - NH00GG50V125 See product
125A NH00 - Yes 0.2kg
R215686 - NH0GG50V20 See product
20A NH0 - Yes 0.27kg
R217733 - NH2GG50V200 See product
200A NH2 - Yes 0.42kg
R222494 - NH2GG50V250 See product
250A NH2 - Yes 0.42kg
R228520 - NH1GG50V355 See product
355A NH1 - Yes 0.42kg
S1069079 - NH3GG50V80 See product
80A NH3 - Yes 0.65kg
S215687 - NH1GG50V80 See product
80A NH1 - Yes 0.28kg
Back to top