Back
Where to buy Contact us
PHP-LFBCG5-MSL

NH fuse-links gG 500VAC , double indicator/live gripping-lugs size 000, 00, 0, 1, 2, 3

Approvals & Standards
VDE 0636 Part 201
IEC 60269-1 and -2

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Key features & benefits

  • Dimensions according to DIN 43 620 parts 1 to 4

  • Non-isolated gripping lugs

  • Double indicator

  • 0% cadmium

Applications

  • gG: general purpose cable and line protection

Technical Specifications

Amperage Range 2 ... 800 A
Speed/Characteristic gG
CE Conformity Yes
Reach Compliant Yes

Reference Finder

Item number Ampere rating Fuse size Clearing I2t At Rated Voltage Indication System Product weight
N212463C - NH000GG50V40/3 See product
40A NH000 - Yes 0.13kg
N218765 - NH0GG50V63 See product
63A NH0 - Yes 0.27kg
P200803 - NH2GG50V300 See product
300A NH2 - Yes 0.64kg
P201861 - NH2GG50V35 See product
35A NH2 - Yes 0.42kg
P211084 - NH00GG50V160 See product
160A NH00 - Yes 0.2kg
P217731 - NH0GG50V40 See product
40A NH0 - Yes 0.27kg
P218766 - NH1GG50V200 See product
200A NH1 - Yes 0.42kg
P222492 - NH0GG50V125 See product
125A NH0 - Yes 0.27kg
Q201862 - NH2GG50V355 See product
355A NH2 - Yes 0.64kg
Q215179 - NH0GG50V16 See product
16A NH0 - Yes 0.27kg
Back to top